
PSC ACTION codes, rectification deadlines and how to handle each
On a port State control report it is the ACTION code, not the deficiency code, that sets the ship's schedule. This is what each code means and where readings diverge.
PSC action codes and concentrated inspections, and the targeting, detention and appeal rules of the Paris MoU and EU, the Tokyo MOU and the US Coast Guard.
24 articles

On a port State control report it is the ACTION code, not the deficiency code, that sets the ship's schedule. This is what each code means and where readings diverge.

The Tokyo MOU and Paris MoU concentrated inspection campaign on cargo securing covers 1 September to 30 November 2026. What each questionnaire item looks at, which items can lead to detention, and the documents a ship should have ready.

The Paris MoU ship risk profile read from Annexes 7, 8 and 9 of the 46th Amendment. The 5-point HRS threshold, where deficiency counts go, two detentions and refusal of access, set beside Tokyo MOU and worked through the same ships.

EU port State control sets inspection intervals and scope from the ship risk profile. How far apart the eligibility point and the ceiling sit for each profile, and the grounds that leave no discretion.

EU port State control keeps the door that postpones an inspection and the door that holds a ship in port inside one directive. The conditions a postponement has to meet, the four categories eligible for an expanded inspection, and the duty to remain until it is finished.

Who do pilots and port authorities report an anomaly seen on board to, and what goes into the report. The path by which that report becomes grounds for an additional inspection and a more detailed inspection, traced through Article 23 and the annexes.

A ship may leave even where the deficiency cannot be fixed in that port. Conditions attach to the voyage, and those conditions and the ship's arrival travel between the next authority and the port of departure.

Repeated detention in the EU turns into refusal of access, and the wait before it lifts grows at each step. The detention thresholds, the detention counts that differ by flag performance list, and the route to a permanent refusal.

The directive grants a right of appeal against detention and refusal of access, and in the same paragraph denies it suspensive effect. What an upheld appeal actually restores, and the qualification and independence conditions placed on inspectors.

A Paris MoU more detailed inspection includes at least one operational control. How the PSCO builds a drill scenario with the master, which required times need not be met on the day, where the report records it, and the report left with a detention.

A Paris MoU PSCO does not audit ISM but judges whether the deficiencies found show a failure to implement it. The four routes from individual deficiencies to an ISM deficiency, the re-inspection after 3 months, and detention on documents alone.

How Paris MoU PSCOs cross-check seafarer certificates, flag State endorsements, the minimum safe manning document and hours of rest records, in the order of the guidance, with hypothetical endorsement expiry and crew list examples.

A Paris MoU PSCO looks at ECDIS through four elements, equipment, charts, backup and proficiency. Deciding whether carriage is required, the demonstration expected of the watch officer, the five grounds for a more detailed inspection, and where detention decisions come from.

A walk through the Paris MoU guidance on load line inspections in the order of initial inspection, clear grounds, more detailed inspection and detention, with a hypothetical voyage showing how submerged marks are treated at each stage.

The Paris MoU guidance PSCC 58/2025/16 read in inspection order. Pre-boarding checks, document cross-checks, the 18 clear grounds, the more detailed inspection, the 8 detention grounds and past violations, followed through a hypothetical case.

The checks a crude oil washing tanker meets in a Paris MoU port, from PSCC 59/2026/09. Six documents, personnel qualifications, oxygen and washing conditions, ORB code D against the Manual, and a multi-port discharge as a hypothetical case.

When a coastal State sights a slick and asks the next port to investigate, what does the PSCO copy and ask? The evidence list in Paris MoU PSCC 59/2026/10, with the ship's rebuttal records checked against the 30-day window.

How Paris MoU PSCOs inspect cargo ships and high-speed cargo craft carrying more than 12 industrial personnel, covering application dates by construction, the two ways people are counted, training records and detainable deficiency codes.

In the Paris MoU region accidental damage deficiencies are recorded without a detention order. The procedure for a single voyage to a repair port when the damage cannot be fixed there, the ballast voyage rule, and what happens after the ETA, compared with detained ships.

A reading of the NIR, the inspection selection scheme in the Tokyo MOU region. How the four weighting points for HRS add up, the all-criteria test for LRS, the company performance formula, and the inspection windows, worked through three hypothetical ships.

How Tokyo MOU attributes a detainable deficiency to the RO. The issuer and last surveyor combinations, the timing test and 90 days for each deficiency type, the three exclusions, and what a master can expect of a PSCO.

A comparison of detention appeal procedures across the 22 Tokyo MOU Authorities by starting date, deadline, who may file, language and review stages, with a hypothetical calendar for deadlines from 10 days to 3 months.

USCG Qualship 21 and E-Zero are programmes for foreign-flagged ships calling at US ports. What the revision in force from 14 January 2026 changed in flag requirements, exit criteria and conditional renewal, and the entry and exit conditions.

Foreign ships calling at US ports are selected for examination through the USCG targeting matrix. The matrix's six inputs, the flag targeting criteria, the 78 detentions and deficiency breakdown in the 2025 annual report, and the appeal process.